archive-ca.com » CA » G » GRIDFLOW.CA

Total: 601

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".

  • doc m o0 symbol X text 232 548 numtype X obj 56 105 type gui X obj 56 137 display X obj 156 137 display X text 144 47 abbreviated output X text 50 48 regular output X obj 298 188 display X obj 424 188 display X text 422 48 abbreviated output X text 300 48 regular output X text 55 30 horizontal with letter labels X text 336 30 vertical with full labels X obj 97 464 doc m i0 vertical X text 232 464 0 horizontal see above X text 232 486 1 vertical see above too X text 54 64 type gui X text 144 64 type gui abbr X text 291 64 type gui vertical X text 421 64 type gui vertical abbr X obj 156 105 type gui abbr X obj 298 106 type gui vertical X obj 424 106 type gui vertical abbr X obj 56 86 r 0 a X obj 156 86 r 0 a X obj 298 87 r 0 a X obj 424 87 r 0 a X obj 37 281 s 0 a X msg 52 160 symbol uint8 X msg 52 180 symbol int16 X msg 52 200 symbol int32 X msg 52 220 symbol int64 X msg 52 240 symbol float32 X msg 52 260 symbol float64 X obj 147 281 s 0 a X msg 162 160 symbol b X msg 162 180 symbol s X msg 162 200 symbol i X msg 162 220 symbol l X msg 162 240 symbol f X msg 162 260 symbol d X connect 1 1 3 0 X connect 1 1 4 0 X connect 1 1 5 0 X connect 11 1 12 0 X connect 13 1 14 0 X connect 13 1 15 0

    Original URL path: http://gridflow.ca/svn/trunk/doc/flow_classes/%23type-gui-help.pd (2013-06-03)
    Open archived version from archive



  • X obj 17 65 type X symbolatom 17 84 10 0 0 0 X msg 27 38 3 3 f 10 4 X text 232 187 the number type of this grid will be output X obj 97 235 doc m i0 abbr X text 232 235 whether single letter abbreviations will be output instead of the full name X obj 232 209 doc link numtype 1 X obj 205

    Original URL path: http://gridflow.ca/svn/trunk/doc/flow_classes/%23type-help.pd (2013-06-03)
    Open archived version from archive


  • 14 202 doc ii 0 X obj 14 272 doc ii 1 X obj 97 237 doc m i0 state X text 232 272 same as state X obj 97 202 doc m i0 grid X obj 97 272 doc m i1 bool X obj 3 366 doc also X obj 103 366 out X text 232 202 as with out window when state 1 else ignored when state 0

    Original URL path: http://gridflow.ca/svn/trunk/doc/flow_classes/%23window-help.pd (2013-06-03)
    Open archived version from archive




  • unsigned full range YUV format This means that normal black is 0 128 128 and normal white is 255 128 128 X text 232 410 this actually works on any grid of pixels dim 3 X text 232 472 a grid of the same size as the input in RGB format X obj 97 472 doc m o0 grid X obj 97 362 doc m i0 grid X obj 127 137 many nbx 1 3 X obj 9 57 tgl 15 0 empty empty empty 17 7 0 10 262144 1 1 1 1 X obj 9 93 store X obj 75 38 loadbang X obj 9 74 metro 50 X obj 9 232 clip X obj 9 140 128 X obj 9 178 128 X obj 127 99 loadbang X msg 127 118 1 3 256 256 256 X msg 75 57 load colorpanorama jpg X obj 75 76 in X msg 99 76 load pure data jpg X text 107 166 control contrast of individual Y U V channels relatively to the middle of their ranges X connect 7 0 24 0 X connect 8 0 23 0 X connect 9 1 10 0 X connect 12 0

    Original URL path: http://gridflow.ca/svn/trunk/doc/flow_classes/%23yuv_to_rgb-help.pd (2013-06-03)
    Open archived version from archive


  • of arguments X text 37 224 do whatever you want with those args X obj 246 265 t a X text 253 246 anything else coming from first inlet or named args X obj 172 145 display X floatatom 38 263 5 0 0 0 X floatatom 97 263 5 0 0 0 X text 249 91 world defaults to 42 X text 176 126 hello mandatory argument X obj 246 284 display X text 34 70 mandatory left inlet X text 33 84 for using args with X text 33 96 a comma X obj 412 107 list length X floatatom 412 126 5 0 0 0 X obj 409 157 listflatten X obj 409 197 list length X floatatom 409 216 5 0 0 0 X obj 415 177 display X text 344 33 WARNING nested lists can be troublesome X text 123 319 a nested list argument becomes a normal list when coming out of an args outlet X connect 0 0 11 0 X connect 0 1 6 0 X connect 0 2 5 0 X connect 0 2 20 0 X connect 0 2 22 0 X connect 2 0 3 0 X connect 3

    Original URL path: http://gridflow.ca/svn/trunk/doc/flow_classes/args-demo.pd (2013-06-03)
    Open archived version from archive


  • 748 doc m oany X text 232 560 sends one message per outlet right to left if there is a wildcard as the last argument any extra arguments go there as a list message Then for any missing arguments that have default values the default values are sent right to left Then for each present argument that is not extra that argument will be sent on its own outlet Finally each init message comma separated is parsed from the arguments and sent magically to the first inlet of the abstraction itself X text 232 415 represent optional arguments as nested lists X text 232 437 inside the nested list 1 must be the name of the argument 2 must be a the single letter and 3 must be the default value the a is actually for future use type checking X text 232 380 the star can only occur once and at the end and all optionals must follow all mandatories X obj 12 37 cnv 15 100 25 empty empty Warning 0 8 0 14 262144 258113 0 X obj 97 560 doc m i0 loadbang X obj 97 538 doc m i0 bang X text 232 538 Same as loadbang X text 103 37 When using args inside a patch that also uses a loadbang for stuff that depends on those arguments you need to make sure that the loadbang in question is created AFTER args This is the same problem as what happens with the order of multiple loadbang objects because args is implicitly a loadbang too X obj 97 415 doc m cany X obj 3 780 doc also X text 105 121 If you don t want to deal with it you can connect an explicit loadbang to args but be warned that everything will

    Original URL path: http://gridflow.ca/svn/trunk/doc/flow_classes/args-help.pd (2013-06-03)
    Open archived version from archive


  • X obj 14 195 doc ii 0 X obj 14 257 doc oo 0 X obj 3 125 doc c 0 X obj 97 195 doc m i0 float int X obj 97 257 doc m o0 float X obj 0 348 doc f X msg 86 40 1e 06 X obj 3 328 doc also X obj 103 328 ascii to f X text 232 257 a sequence of

    Original URL path: http://gridflow.ca/svn/trunk/doc/flow_classes/ascii-help.pd (2013-06-03)
    Open archived version from archive


  • X obj 97 266 doc m o0 float X text 232 327 integer coming from inlet 0 but unrecognised X text 232 204 ascii bytes integer X floatatom 31 94 8 0 0 0 X obj 88 94 display X msg 31 56 51 46 49 52 49 53 57 51 0 X text 232 266 float value successfully parsed note that this is output only when an unrecognised character

    Original URL path: http://gridflow.ca/svn/trunk/doc/flow_classes/ascii_to_f-help.pd (2013-06-03)
    Open archived version from archive